A network for a building fibre doesn't reach.

A multi-storey residential facility with a single ADSL line. Two satellite dishes we installed, thirteen access points. Goal: a stable, low-maintenance network that stays online even if one dish drops.

Sector
Residential facilities
Practice
Networking
Year
2026
How it works
Satellite
Starlink 1VLAN A
Starlink 2VLAN B
Building network
Two lines, two VLANs, each backs up the other
Managed PoE switch13 access pointsUniFi controllerVLAN A and VLAN BFailoverRadio call in every room
Building
Floors and roomsVLAN A
Front officeVLAN B
BasementVLAN B
In brief

In a residential facility that only had a 6 Mbit ADSL line, we installed two Starlink dishes and built the network, with each line on its own VLAN: the first serves floors and rooms through thirteen UniFi access points, the second the front office and the basement. The two lines back each other up: if one drops, failover moves its traffic to the other and the building stays online. We completed the setup with phone repeaters on every floor and radio call in every room.

2
Starlink links on separate VLANs, with failover
13
UniFi access points
6 Mbit
the ADSL line there before, downstream

Context

The facility houses residents and staff across several floors, from the basement to the fourth floor. With no fixed line, connectivity goes through satellite. Before we started there was only an ADSL line, 6 Mbit down and 0.8 up, for the whole building. We installed both Starlink dishes and built the network.

The problem

With 6 Mbit down and 0.8 up for a whole building, room Wi-Fi and front-office work couldn't coexist. And two dishes alone don't make a redundant network: you have to decide how to use them. The client wanted the most stable, lowest-maintenance option. With two lines used independently, a dish losing signal leaves part of the building offline: real redundancy means each line can take the other's place.

What we did

  1. 01

    Two VLANs, one per line

    The network is split into two VLANs. VLAN A goes out over Starlink 1 and serves the floor and room access points. VLAN B goes out over Starlink 2 and serves the front office and the basement. Normally traffic is split, so the two parts of the building don't compete for the same bandwidth.

  2. 02

    Failover between the lines

    If one dish stops responding, its VLAN's traffic moves to the other line with no manual action. When the line is back, each VLAN returns to its own uplink. Satellite latency varies, so the line check relies on lost connectivity rather than a single slow ping.

  3. 03

    Phone and radio call

    We completed the setup with phone repeaters on every floor and a radio call system in every room of each floor, so residents and staff can reach each other anywhere in the building.

  4. 04

    Access

    A keypad installed for controlled entry.

How it went

The network covers the building from the basement to the fourth floor with two satellite lines on separate VLANs and the access points managed from one controller. If one line drops, the other takes over: residents, staff and front office stay connected.

Tools

StarlinkUniFiVLANFailoverManaged PoE switchPhone repeatersRadio call system

FAQ

Is Starlink suitable for a care or hospitality facility?

Yes, where fixed lines don't reach or aren't reliable, as long as redundancy is designed in: two dishes on separate VLANs, with failover from one to the other. Starlink uses CGNAT, so without a plan with a dedicated IP you can't open inbound ports: keep that in mind for cameras and remote access.

Why two VLANs rather than one network on two lines?

With two VLANs each part of the building has its own main line and bandwidth isn't contended, while failover makes sure one line covers the other if it fails. For real-time connections such as calls, a main line with a backup is more stable than constant balancing across two satellite links.

What happens when a dish loses signal?

The traffic of the VLAN tied to that dish moves to the other line. Open connections may take a moment to reconnect, then the network carries on; when the dish is back online, each VLAN returns to its own uplink.

Contact

Facing something similar?

Tell us what you run today and what isn't working. We'll reply within one business day with a first technical read.

Email
hello@cloudfactory.it
Address
Viale di Trastevere 114, 00153 Rome, Italy